Our commission would be to serve our customers and clientele with very best excellent and aggressive portable digital products for Overload Protection High Flow Oxygen PlantHome Health Oxygen Machine3l Home Use Elite Oxygen Making Machine, Our company quickly grew in size and reputation because of its absolute dedication to high quality manufacturing, high value of products and excellent customer service.

Good Quality Patient Monitor – Aurora-10 10.4-inch patient monitor optional touch screen Wifi connection for hospital ICU

PRODUCT DETAIL

  • Indication of incorrect manipulation and malfunction analysis
  • Patient info input management function
  • Multi-lead ECG waveforms display in phase
  • Large volume of tabular and graphic trends information storage and easy to recall
  • Capture dynamic waveforms
  • Up to 5 hours working capacity of built-in rechargeable lithium battery
  • Unique accessory management cabinet Networking capacity
  • Option: EtCO2, 5AH Lithium battery, wireless communication module (WIFI, GPRS), touch screen, IBP, AG.
Aurora 10

Accessories

Aurora 10

Technique Parameter

Standard configuration
Screen
Display Type 10″ color TFT LCD
Resolution 800×600 pixels
Waveforms Up to 7
ECG
Input 3/5 wire ECG cable
Lead section I II III aVR, aVL, aVF, V
Gain selection *0.25, *0.5, *1, *1.2
Sweep speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Heart rate range 15-30bpm
Calibration ±1mv
Accuracy ±1bpm or ±1% (select the bigger data)
NIBP
Test method Oscillometer
Philosophy Adult, Pediatric and Neonate
Measurement type Systolic Diastolic Mean
Measurement parameter Automatic, Continuous measurement
Measurement method Manual mmHg or ±2%
SPO2
Display Type Waveform, Data
Measurement range 0-100%
Accuracy ±3% (between 70%-100%)
Pulse rate range 20-300bpm
Accuracy ±1bpm or ±2% (select the bigger data)
Resolution 1bpm
2-Temperature (Rectal & Surface)
Number of channels 2 channels
Measurement range 0-50℃
Accuracy ±0.2℃
Display T1, T2, ☒T
Unit  ºC/ºF selection
Refresh cycle 1s-2s
Respiration (Impedance & Nasal Tube)
Measurement type 0-150rpm
Accuracy ±1bm or ±5%, select the bigger data
Resolution 1rpm
Optional configuration
EtCO2-Plug & Play
Measurement type Side stream
Measurement range 0-10.0%; 0-76mmHg
Accuracy <5.0%, ±0.28kPa; ±2mmHg
>5.0%, ±10%
2-IBP (optional)
Measurement range 10~300mmHg
Number of channels 1 or 2 channels
Accuracy ±1mmHg or ±2%, select bigger data
Pressure tag ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP
12 leads ECG (optional)
Input 3/5/10 wires ECG cable
Lead section I, II, III aVR, aVL, aVF, V(V1-V6)
Heart rate range 15-380bpm
Calibration ±1mv