Aurora 8

  • 5 Standard parameters: ECG, NIBP, SpO2, RESP, Temp
  • 8.4-inch high resolution industry color TFT LCD display
  • Real time S-T segment analysis, pace-maker detection
Aurora-8 8.4-inch multi parameter patient monitor for ambulance and transport
Aurora 8
Aurora 8

PRODUCT DETAIL

  • Indication of incorrect manipulation and malfunction analysis
  • Patient info input management function
  • Multi-lead ECG waveforms display in phase
  • Large volume of tabular and graphic trends information storage and easy to recall
  • Capture dynamic waveforms
  • Up to 5 hours working capacity of built-in rechargeable lithium battery
  • Unique accessory management cabinet Networking capacity
  • Option: EtCO2, 5AH Lithium battery, wireless communication module (WIFI, GPRS), touch screen, IBP, AG.
Aurora 8

Accessories

Aurora 8

Technique Parameter

Standard configuration
Screen
Display Type 8″ color TFT LCD
Resolution 800×600 pixels
Waveforms Up to 7
ECG
Input 3/5 wire ECG cable
Lead section I II III aVR, aVL, aVF, V
Gain selection *0.25, *0.5, *1, *1.2
Sweep speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Heart rate range 15-30bpm
Calibration ±1mv
Accuracy ±1bpm or ±1% (select the bigger data)
NIBP
Test method Oscillometer
Philosophy Adult, Pediatric and Neonate
Measurement type Systolic Diastolic Mean
Measurement parameter Automatic, Continuous measurement
Measurement method Manual mmHg or ±2%
SPO2
Display Type Waveform, Data
Measurement range 0-100%
Accuracy ±3% (between 70%-100%)
Pulse rate range 20-300bpm
Accuracy ±1bpm or ±2% (select the bigger data)
Resolution 1bpm
2-Temperature (Rectal & Surface)
Number of channels 2 channels
Measurement range 0-50℃
Accuracy ±0.2℃
Display T1, T2, ☒T
Unit  ºC/ºF selection
Refresh cycle 1s-2s
Respiration (Impedance & Nasal Tube)
Measurement type 0-150rpm
Accuracy ±1bm or ±5%, select the bigger data
Resolution 1rpm
Optional configuration
EtCO2-Plug & Play
Measurement type Side stream
Measurement range 0-10.0%; 0-76mmHg
Accuracy <5.0%, ±0.28kPa; ±2mmHg
>5.0%, ±10%
2-IBP (optional)
Measurement range 10~300mmHg
Number of channels 1 or 2 channels
Accuracy ±1mmHg or ±2%, select bigger data
Pressure tag ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP
12 leads ECG (optional)
Input 3/5/10 wires ECG cable
Lead section I, II, III aVR, aVL, aVF, V(V1-V6)
Heart rate range 15-380bpm
Calibration ±1mv